How to couple 2.5V LVPECL to a differential receiver with a 0.8V DC input requirement for IDT timing devices

AC coupling a 2.5V LVPECL signal to a differential receiver with a 0.8V common mode input requirement can be accomplished using a small number of passive components. Assume the receiver is high input impedance without built-in matched load termination. See the solution below. For other questions not addressed by the Knowledge Base, please submit a technical support request.