How to couple 2.5V LVPECL to a differential receiver with a 1.25V DC input requirement for IDT timing devices

AC coupling a 2.5V LVPECL signal to a differential receiver with a 1.25V common mode input requirement can be accomplished using a small number of passive components. See the solution below. For other questions not addressed by the Knowledge Base, please submit a technical support request.